Rockwell Automation Publication GMC-RM009D-EN-P - June 2014
Kinetix 5500 Drive Systems
Kinetix 5500 (400V-class operation) Drives with Kinetix VP Stainless Steel Motors
This section provides system combination information for the Kinetix 5500 drives (with 480V, nominal input) when
matched with Kinetix VP (400V-class) stainless-steel motors. Single cable catalog numbers, system performance
specifications, and the optimum torque/speed curves are included.
Bulletin VPS Motor Cable Combinations
Bulletin VPS Motor Performance Specifications with Kinetix 5500 (400V-class operation) Drives
Kinetix 5500 (400V-class operation) Drives/Kinetix VP Stainless Steel Motor Curves
Motor Cat. No. (400V-class)
Feedback Type
Motor Feedback Cable
(1)
(1) Cable length
xx is in meters, 01 (3.3)…50 (164) in 1.0 m (3.3 ft) increments. Refer to the Kinetix Motion Accessories Technical Data, publication
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Single Motor Cable Overview beginning on
VPS-B1304D
Multi-turn or Single-turn
Digital Encoder Feedback
2090-CSWM1DF-14AA
xx (standard, non-flex)
2090-CSBM1DF-14AF
xx (continuous-flex)
VPS-B1653D
Rotary Motor
Speed, max
rpm
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Stall Torque
N•m (lb•in)
Motor Rated
Output
kW
Kinetix 5500 Drives
(480V AC input)
VPS-B1304D
3000
7.1
8.1 (72.0)
17.7
17.9 (158)
1.40
2198-H015-ERS
x
26.0
27.1 (240)
2198-H025-ERS
x
VPS-B1653D
3000
17.0
21.0 (186)
45.9
50.1 (443)
3.29
2198-H040-ERS
x
68.0
67.8 (600)
2198-H070-ERS
x
Torque
(N•m)
Torque
(lb•in)
2198-H025-ERS
x and VPS-B1304D
30
25
20
15
10
5
0
265
221
177
133
88.5
44.2
0
Speed (rpm)
0
3000
2000
1000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2198-H070-ERS
x and VPS-B1653D
708
531
354
177
0
0
1000
80.0
60.0
40.0
20.0
0
1500
500
3000
2500
2000
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC rms input voltage