Rockwell Automation FactoryTalk Historian SE 3.0 H2H Interface User Guide User Manual
Page 74

Startup Command File
68
.BAT
.INI
Description
/ist=tagname
Optional
--
Name of interface status tag.
/ist=
where <
tagname
> is a digital tag on the
receiving Historian Server.
/ln=username
Optional
SourceLogin
Login name of PI user on Historian 2 node.
This is used when source server is Historian
2.
/oc=#
Optional
Default:
/oc=30
--
Number of seconds between calculating time
offset between the interface and Historian
Server nodes.
/ps=x
Required
--
The
/ps
parameter specifies the point
source for the interface.
X
is not case
sensitive and can be any single or multiple
character string. For example,
/ps=P
and
/ps=p
are equivalent.
The point source that is assigned with the
/ps
parameter corresponds to the
PointSource attribute of individual Historian
Points. The interface will attempt to load only
those Historian Points with the appropriate
point source.
/pw=password
Optional
SourcePassword
Login password of PI user on Historian 2
node. This is used when source server is
Historian 2.
/sf=filename
Required for Historian
2 source
SecurityFile
Used for locating the security file on a PI2
source server.
This switch specifies the
file name. Note that the complete file name
must have this format:
PItoPI
where
/sf
/src_host=name:
port
Required
SourceHost
Name or IP address of source Historian
Server.
/src_host=node_name:tcpip_port
The port number is 545 (Historian 2) or 5450
(Historian 3).