beautypg.com

Rockwell Automation FactoryTalk Historian SE 3.0 H2H Interface User Guide User Manual

Page 58

background image

Startup Command File

52

Interface name as displayed in the ICU (optional) will have Historian- pre-pended to this
name and it will be the display name in the services menu.

Click Add.

The following display should appear:

Note that in this example the Host FactoryTalk Historian System is mkellyD630. To
configure the interface to communicate with a remote Historian Server, select „Interface =>
Connections…
‟ item from ICU menu and select the default server. If the remote node is not
present in the list of servers, it can be added.

Once the interface is added to ICU, near the top of the main ICU screen, the interface Type
should be

PItoPI

. If not, use the drop-down box to change the interface Type to be

PItoPI

Click on Apply to enable the ICU to manage this copy of the FactoryTalk Historian to
Historian Interface.

The next step is to make selections in the interface-specific page (that is, PItoPI) that allow
the user to enter values for the startup parameters that are particular to the FactoryTalk
Historian to Historian Interface.