MinPak Plus
SingleĆPhase DĆC
Controller Description
The Reliance Electric MinPak Plus
SingleĆPhase DĆC Controller is a
fullĆwave power converter without
back rectifier, complete with an
analog current minor loop and an
analog major loop for armature
voltage or speed regulation by
tachometer feedback. The product
line has been setĆup to be sold as
listed in Table 2Ć1.
The Controller is provided, as
standard, in a NEMA Type 4/12
enclosure intended for wall or panel
mounting. It is made up of a chassis
and hinged cover. (Type 4 may be
generally defined as a washĆdown"
design. The enclosure may be
easily converted into a chassisĆonly
type configuration for panel
mounting within a large electrical
enclosure. An optical remote control
station may then be placed on the
larger enclosure's face or some
distance away.
A single power POWER ON/OFF
circuit breaker is standard with each
chassis and is independent of the
cover and faceplate.
For proper operation of the
Controller, it is necessary to use an
Operator's Station. The Operator
Stations allow the tailoring of control
functions for the application.
There are two basic configurations
that may be selected:
D Local Station - station mounted
on Controller Chassis Cover
D Remote Station - station
mounted remotely as a separate
unit
Local Station
Available is a selection of 8
standard Faceplates in order to
configure a controller to a specific
drive application. Refer to Table
2Ć1A. The Faceplate design
maintains the NEMA Type 4/12
rating assuming the Cover is
properly installed.
Table 2Ć1. Controller Model Numbers
Model Number
Optional
Transf.
KVA
Enclosed Chassis
HP
VAC
(3)
AĆC
Amps
(RMS)
DĆC
Arm.
(Volts)
DĆC
Arm.
Amps
Avg.
DĆC
Field
Volts
Amp.
MAX
Power
Supply
Capacity
(2)
MAX
MIN
14C10
14C20
1/4
115
3.5
90
2.5
100
3.0
1000
40.0
0.50
1/3
115
5.2
90
3.7
100
3.0
1000
40.0
0.75
1/2
115
7.0
90
5.0
100
3.0
1000
40.0
1.50
3/4
115
10.5
90
7.5
100
3.0
1000
40.0
1.50
14C11
14C21
1/2
230
3.5
180
2.5
200
3.0
1000
40.0
1.50
3/4
230
5.2
180
3.7
200
3.0
1000
40.0
1.50
1
230
7.0
180
5.0
200
3.0
1000
40.0
2.00
1 1/2
230
10.5
180
7.5
200
3.0
5000
40.0
3.00
14C12
14C22
2
230
14.0
180
10.0
200
3.0
1
5000
40.0
5.00
3
230
21.0
180
15.0
200
3.0
1
5000
40.0
10.0
14C13
14C23
5
230
35.0
180
25.0
200
3.0
1
5000
40.0
10.0
1
Standard
2
Maximum permissible available symmetrical RMSfault current (amperes) with NEC or CEC external approved disconnect.
3
Does not include current required for Field Supply (if used).