P.026, P.027, P.028 – Rockwell Automation GV3000/SE AC Drive ControlNet Network Communication Board, M/N 2CN3000 User Manual
Page 92: P.029, P.030, P.031, P.032, P.033, P.034, P.035

7-2
GV3000/SE AC Drive ControlNet Network Communication Option Board
N10:26
Function Loss Response
P.026
Tunable
0 = IET; 1 = Coast
N10:27
Forward/Reverse Configure
P.027
Tunable
0 = enable; 1 = rev. disable; 2 = latch
N10:28
Speed Display Scaling
P.028
Tunable
Units
N10:29
Elapsed Time Meter
P.029
Read Only
Days
N10:30
Control Bits
P.030
bit 0 = Elapsed Time Reset
bit 1 = CNI Inertia Compensation
bit 2 = CNI Speed PI Limit Enable
N10:31
Preset Speed 1
P.031
Tunable
50 = 5.0 Hz / 150 = 150 RPM
N10:32
Preset Speed 2
P.032
Tunable
50 = 5.0 Hz / 150 = 150 RPM
N10:33
Preset Speed 3
P.033
Tunable
50 = 5.0 Hz / 150 = 150 RPM
N10:34
Preset Speed 4
P.034
Tunable
50 = 5.0 Hz / 150 = 150 RPM
N10:35
Preset Speed 5
P.035
Tunable
50 = 5.0 Hz / 150 = 150 RPM
N10:36
Preset Speed 6
P.036
Tunable
50 = 5.0 Hz / 150 = 150 RPM
N10:37
Preset Speed 7
P.037
Tunable
50 = 5.0 Hz / 150 = 150 RPM
N10:38
Preset Speed 8
P.038
Tunable
50 = 5.0 Hz / 150 = 150 RPM
N10:39
Encoder Loss Enable
P.039
Tunable
0 = off; 1 = on
N10:40
Motor Overload Enable
P.040
Configurable 0 = off; 1 = on
N10:41
Motor Overload Type
P.041
Configurable 0 = nC; 1 = FC
N10:42
Line Dip Ride-Through Time
P.042
Configurable 1 = 0.1sec
N10:43
Fault Auto Reset Attempts
P.043
Configurable 0 to 10
N10:44
Fault Auto Reset Time
P.044
Configurable 8 = 8 sec
N10:45
Output Phase Loss Enable
P.045
Tunable
0 = off; 1 = on
N10:46
Reserved
P.046
Note 1
N10:47
Carrier Frequency (kHz)
P.047
Configurable 0 = 2 kHz; 1 = 4 kHz; 2 = 8 kHz
N10:48
V/Hz or Vector Regulation
P.048
Configurable 0 = V/Hz; 1 = Vector
N10:49
Country Defaults
P.049
Configurable 0 = USA; 1 = EUr; 2 = JPn
N10:50
Restore Defaults
P.050
Note 1
N10:51
Programming Disable
P.051
Tunable
Enter the password (26)*
N10:52
AUTO/MAN Key Disable
P.052
Tunable
0 = off; 1 = on
N10:53
Manual Ref. Preset Enable
P.053
Tunable
0 = off; 1 = on
N10:54
Level Sense Start Enable
P.054
Configurable 0 = off; 1 = on
N10:55
STOP/RESET Key Disable
P.055
Tunable
0 = off; 1 = on
N10:56
Reserved
P.056
Note 1
N10:57
Reserved
P.057
Note 1
* When you write to P.051, entering the password toggles disabling programming from the drive keypad. When you
read P.051, 0 = programming enabled, 1 = programming disabled.
Table 7.1 – File N10:X (Drive Read/Write Parameters)
File
Address
Parameter Name
Parameter
Number
Type
Notes
Note 1: This parameter cannot be changed from the ControlNet network, or it is reserved. When writing to this parameter, use
a value of 0. When you read this parameter, you receive a value of 0.