Additional information for 2706-p9x displays -6 – Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual
Page 44
Publication 2706-UM016D-EN-P - March 2006
2-6 InView System Connectivity
The dip switch setting takes priority over the software setting. If the
serial address is set to 2 using the software (all the dip switches set to
off) and then Switch 2 is used to set the serial address to 3 (position 1
and 2 set to on and the remaining positions set to off), the serial
address is 3. Also, once Switch 2 is used to set the serial address and
then all switch positions are set to off, the serial address setting
remains until it is changed by software or the dip switch is set.
.2706-P9x Dip Switch Settings
Additional Information for 2706-P9x Displays
For additional information on communication port wiring and display
configuration, refer to the InView Marquee Message Display User
Manual, publication 2706-UM016.
This product contains a Lithium battery. See publication 2711P-IN009
for information regarding battery replacement and disposal.
Communications Board Kits
There are optional Communications Board Kits available for the
2706-P9 series displays. There are a total of six board kits:
• Remote I/O (2706-PRIOK)
• DH+ (2706-PDHPK)
• DH-485 (2706-PDH485K)
• ControlNet (2706-PCNETK)
• DeviceNet (2706-PDNETK)
• EtherNet/IP (2706-PENETK).
Size
ON = P92C
OFF = P94C
RS485
Echo
Baud Rate
3 4
OFF OFF = Software
Default
ON OFF = 9600
OFF ON = 19200
ON ON = 38400
Display Address
Switch
1
2
3
4
5
6
7
8
Value
1
2
4
8
16
32
64
128
LSB
MSB
Not
Used
Not
Used
ON =
Diagnostics
ON =
Disable
Download
Message