Change the inview display address -40, Change the inview display address – Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual
Page 106

Publication 2706-UM016D-EN-P - March 2006
4-40 InView Protocol
The normal response to a function 03 query is to echo the address,
function code, starting address and the data for the registers that were
requested.
Response for Requesting Variable Data
Change the InView Display Address
This function allows the ability to change the serial address in a
display. For example change display address 001 to address 020.
When doing this, you need to know the address of the display you
want to change. This is typically done using the automation software.
The following is an example of changing a display (with the address
of 005) to address 004.
Transmission:
Transmission for Changing the Serial Address
Response: NONE
Beginning
of Frame
ADDR
FUNC
BYTE
COUNT
DATA
OUTPUT
REG H.O.
0002
DATA
OUTPUT
REG L.O.
0002
DATA
OUTPUT
REG H.O.
0003
DATA
OUTPUT
REG L.O.
0003
:
14
03
06
00
2C
00
3F
DATA
OUTPUT
REG
H.O.
0004
DATA
OUTPUT
REG L.O.
0004
LRC
EOF
Ready to
rec. resp
00
01
77
CR
LF
Beg of
Frame
ADDR
FUNC
H.O.
ADDR
L.O.
ADDR
DATA
EOF
Ready to rec. resp
:
05
01
00
64
^AZ05^BE704^D
CR
LF
TIP
See section InView Display Communication Protocol
Functions and Descriptions on for further
explanation of the InView sign protocol being used.