The normal response to a function 03 query is to echo the address,
function code, starting address and the data for the registers that were
requested.
Response for Requesting Message Queue Data
Read Variables in a Display using a Modbus ASCII 03 frame
This function allows the ability to read variable data stored in a
display. A maximum of 100 registers can be read since there is a
maximum of 100 registers of data. Below is an example of the request
for registers 40002 through 40004 in display address 020.
Transmission:
Query for Requesting Variable Data
Response:
The addressed slave responds with its address and the function code,
followed by the information field. The information field contains 2
bytes describing the quantity of data bytes to be returned. The
contents of the registers requested (DATA) are two bytes each, with
the binary content right justified within each pair of characters. Below
shows the response to query for registers 40002 through 40004 having
the decimal contents of 44, 63, and 1 respectively.
Beginning
of Frame
ADDR
FUNC
BYTE
COUNT
DATA
OUTPUT
REG H.O.
0066
DATA
OUTPUT
REG L.O.
0066
DATA
OUTPUT
REG H.O.
0067
DATA
OUTPUT
REG L.O.
0067
:
0A
03
06
00
04
00
06
DATA
OUTPUT
REG H.O.
0068
DATA
OUTPUT
REG L.O.
0068
LRC
EOF
Ready to
rec. resp
00
0B
D8
CR
LF
Beginning
of Frame
ADDR
FUNC
H.O.
ADDR
L.O.
ADDR
DATA Number
of register to
read
LRC
Error
EOF
Ready to
rec. resp
:
14
03
00
01
0003
E5
CR
LF