Data File 4 - Timers

Timers are 3-word elements. Word 0 is the control word, word 1
stores the preset value, and word 2 stores the accumulator value. This
is illustrated below.

Assign timer addresses as follows:

Format

Explanation

Tf:e

T

Timer

f

File number.

Number 4 is the default file. A file
number between 10-255 can be used if
additional storage is required.

:

Element delimiter

e

Element
number

Ranges from 0 to 255. These are 3-word
elements. See the figure above.

Examples:

T4:0

Element 0, timer file 4.

Address bits and words by using the format TF:e.s/b where Tf:e is explained above, and

. is the word delimiter
s indicates subelement
/ is the bit delimiter
b indicates bit

T4:0/15
T4:0/14
T4:0/13

T4:0.1
T4:0.2

T4:0.1/0
T4:0.2/0

Enable bit
Timer timing bit
Done bit

Preset value of the timer
Accumulated value of the timer

Bit 0 of the preset value
Bit 0 of the accumulated value

EN

14

TT

DN

12

7

6

5

nternal se

15

13

11 10 9

Preset alue PRE

8

Accumulated alue ACC

4

0

0

1

2

Word

3

2

1

Timer Element

Addressable Bits

Addressable Words

r

o

r

d

d r r o ddr