7 - maintaining your control system, Handling, Storing – Rockwell Automation 1747-L40 SLC 500 Fixed Hardware Style User Manual
Page 86: Maintaining your control system
7
Chapter
7–1
Maintaining Your Control System
This chapter covers the following:
•
handling, storing, and transporting battery, Catalog Number 1747–BA
•
installing or replacing your SLC 500 battery
•
replacing the power supply fuse
•
replacing retainer clips on a module
Refer to chapter 2 for important information on testing the master control
relay circuit and preventive maintenance.
Follow the procedure below to ensure proper battery operation and reduce
personnel hazards.
Handling
•
Use only for the intended operation.
•
Do not ship or dispose of batteries except according to recommended
procedures.
•
Do not ship on passenger aircraft.
!
ATTENTION: Do not charge the batteries. An explosion could
result or they could overheat causing burns.
Do not open, puncture, crush, or otherwise mutilate the batteries.
A possibility of an explosion exists and/or toxic, corrosive, and
flammable liquids would be exposed.
Do not incinerate or expose the batteries to high temperatures.
Do not attempt to solder batteries. An explosion could result.
Do not short positive and negative terminals together. Excessive
heat could build up and cause severe burns.
Storing
Store the lithium batteries in a cool, dry environment, typically +20
°
C to
+25
°
C (+68
°
F to +77
°
F) and 40% to 60% relative humidity. Store the
batteries and a copy of the battery instruction sheet in the original container,
away from flammable materials.
Handling, Storing, and
Transporting Battery, Catalog
Number 1747-BA