Input circuit diagram, Output circuit diagram, E-47 – Rockwell Automation 1747-L40 SLC 500 Fixed Hardware Style User Manual
Page 190: On/off state voltage ranges, Operating voltage range
for Your Fixed Controller
Appendix E
Wiring and Circuit Diagrams and Voltage Ranges
E–47
Input Circuit Diagram
2 7 0
2 6 1
1
µ
F
1 8 7 0
I N
I N
2 7 0
1
µ
F
1 8 7 0
2 6 1
0.15
µ
F
0.15
µ
F
AC COM
On/Off State Voltage Ranges
0 VAC
50 VAC
265 VAC
170 VAC
ЙЙЙЙЙЙЙЙЙЙЙЙ
ЙЙЙЙЙЙЙЙЙЙЙЙ
On-state
Input State Not Guaranteed
Off-state
Output Circuit Diagram
L1
OUT
OUT
Operating Voltage Range
ЙЙЙЙЙЙЙЙЙ
ЙЙЙЙЙЙЙЙЙ
Recommended Operating Range
0 VAC
265 VAC
Operation Not Guaranteed
85 VAC
Important: If you measure the voltage at an output terminal that is not connected to a load or is connected to a high-impedance
load, you may measure as much as 100 VAC even though the output is off.