Cable Entry Plate Removal

If additional wiring access is needed, the cable entry plate on all drive frames can
be removed. Loosen the screws securing the plate to the heat sink and slide the
plate out.

Figure 8 - Frame A, B, C, D Power Terminal Block and DC Bus Test Points

Figure 9 - Frame E Power Terminal Block

Figure 10 - Power Input Terminals on Frame B with Internal RFI Filter Option

Terminal

Description

Notes

R

R (L1)

Three-phase AC line input power.
For single-phase input, connect to any two terminals.

S

S (L2)

T

T (L3)

BR1

DC brake

DB resistor connection - Important: Do not connect both an internal and
external DB resistor at the same time. This can violate the minimum
allowed DB resistance and cause damage to the drive.

BR2

DC brake

U

U (T1)

To the motor

V

V (T2)

To the motor

W

W (T3)

To the motor

PE

PE ground

PE

PE ground

-DC DC

bus

(–)

Test point on Frames A, B, C, and D are to the left or right of the power

terminal block. Frame E has a dedicated terminal.

+DC DC

bus

(+)

L1

R

L2

S

L3

T

BR1

+DC

BR2

BRK

T1

U

T2

V

T3

W

PE PE

-DC

-DC

L1

R

L2

S

L3

T

+DC –DC BR1 BR2

T1

U

T2

V

T3

W

PE

PE

M6

M6

L1

R

L2

S

L3

T

BR1

+DC

BR2

BRK

T1

U

T2

V

T3

W

PE PE

-DC

-DC

L1

R

L2

S

L3

T