beautypg.com

Step 3: wire the drive – wire recommendations, Opening the cover, Ip66 nema/ul type 4x/12 indoor installations – Rockwell Automation 20A PowerFlex 70 Adjustable Frequency AC Drive User Manual

Page 17: 17 ip66 nema/ul type 4x/12 indoor installations

background image

Rockwell Automation Publication 20A-IN009D-EN-P - June 2013

17

PowerFlex 70 Adjustable Frequency AC Drive

Step 3: Wire the Drive – Wire
Recommendations

This section describes wiring recommendations for the drive.

Opening the Cover

To open the cover, follow the steps for your drive enclosure shown below.

IP20 NEMA/UL Type 1

IP66 NEMA/UL Type 4X/12 (for indoor use only)

IP66 NEMA/UL Type 4X/12 Indoor Installations

Use the plugs supplied with IP66 NEMA/UL Type 4X/12 rated drives to seal
unused holes in the conduit entry plate.

For the best seal, be sure that the inner rim of the plug is fully seated against the
edge of the conduit entry hole.

IMPORTANT

Torque cover screws to 0.79 N•m (7 lb•in).

1. Loosen the cover screw.

2. Pull the cover straight off the chassis to
avoid damaging the connector pins.

1. Loosen the cover screws.

2. Pull the cover straight off the chassis.