Parameter cross reference - by name, Parameter cross reference – by name -32, Parameter cross reference – by name – Rockwell Automation 20M LPM15 Liquid-Cooled Adjustable Frequency AC Drive FRN 2.xxx User Manual
Page 80: 32 programming and parameters

3-32
Programming and Parameters
Parameter Cross Reference –
by Name
Parameter Name
Number
Group
Page
Accel Mask
281
Masks & Owners
Accel Owner
293
Masks & Owners
Accel Time X
140, 141
Ramp Rates
Alarm Clear
261
Alarms
3-24
Alarm Config 1
259
Alarms
3-24
Alarm X @ Fault
229, 230
Diagnostics
3-23
Alarm X Code
262-269
Alarms
3-24
Analog In X Hi
322, 325
Analog Inputs
Analog In X Lo
323, 326
Analog Inputs
Analog In X Loss
324, 327
Analog Inputs
Analog In1 Value
16
Metering
3-6
Analog In2 Value
17
Metering
3-6
Analog OutX Hi
343
Analog Outputs
Analog OutX Lo
344
Analog Outputs
Analog OutX Sel
342
Analog Outputs
Anlg In Config
320
Analog Inputs
Anlg In Sqr Root
321
Analog Inputs
Anlg Out Absolut
341
Analog Outputs
Anlg Out Config
340
Analog Outputs
Auto Rstrt Delay
175
Restart Modes
Auto Rstrt Tries
174
Restart Modes
Autotune
61
Torq Attributes
Break Frequency
72
Volts per Hertz
Break Voltage
71
Volts per Hertz
Bus Reg Kd
165
Stop/Brake Modes
Bus Reg Ki
160
Stop/Brake Modes
Bus Reg Kp
164
Stop/Brake Modes
Bus Reg Mode X
161, 162
Stop/Brake Modes
Commanded Freq
2
Metering
3-6
Commanded Speed
2
Metering
3-6
Compensation
56
Torq Attributes
Control SW Ver
29
Drive Data
3-6
Current Lmt Gain
149
Load Limits
Current Lmt Sel
147
Load Limits
Current Lmt Val
148
Load Limits
Data In XX
300-307
Datalinks
Data Out XX
310-317
Datalinks
DB Resistor Type
163
Stop/Brake Modes
DC Brake Level
158
Stop/Brake Modes
DC Brake Time
159
Stop/Brake Modes
DC Brk Lvl Sel
157
Stop/Brake Modes
DC Bus Memory
13
Metering
3-6
DC Bus Voltage
12
Metering
3-6
Decel Mask
282
Masks & Owners
Decel Owner
294
Masks & Owners
Decel Time X
142, 143
Ramp Rates
Dig In Status
216
Diagnostics
3-22
Dig Out Status
217
Diagnostics
3-22
Dig OutX Level
381, 385
Digital Outputs
Dig OutX OffTime
383, 387
Digital Outputs
Dig OutX OnTime
382, 386
Digital Outputs
Digital InX Sel
361-366
Digital Inputs
Digital OutX Sel
380, 384
Digital Outputs
Direction Mask
279
Masks & Owners
Direction Mode
190
Direction Config
3-19
Direction Owner
291
Masks & Owners
DPI Baud Rate
270
Comm Control
DPI Data Rate
270
Comm Control
Drive Alarm X
211, 212
Diagnostics
3-21
Drive Checksum
203
Drive Memory
3-20
Drive Logic Rslt
271
Comm Control
Drive OL Count
219
Diagnostics
3-22
Drive OL Mode
150
Load Limits
Drive Ramp Rslt
273
Comm Control
Drive Ref Rslt
272
Comm Control
Drive Status X
209, 210
Diagnostics
3-20
Drive Temp
218
Diagnostics
3-22
Elapsed MWh
9
Metering
3-6
Elapsed Run Time
10
Metering
3-6
Fault 1 Code
243
Faults
3-24
Fault 1 Time
244
Faults
3-24
Fault 2 Code
245
Faults
3-24
Fault 2 Time
246
Faults
3-24
Fault 3 Code
247
Faults
3-24
Fault 3 Time
248
Faults
3-24
Fault 4 Code
249
Faults
3-24
Fault 4 Time
250
Faults
3-24
Fault 5 Code
251
Faults
3-24
Fault 5 Time
252
Faults
3-24
Fault 6 Code
253
Faults
3-24
Fault 6 Time
254
Faults
3-24
Fault 7 Code
255
Faults
3-24
Fault 7 Time
256
Faults
3-24
Fault 8 Code
257
Faults
3-24
Fault 8 Time
258
Faults
3-24
Fault Amps
225
Diagnostics
3-22
Fault Bus Volts
226
Diagnostics
3-22
Fault Clear
240
Faults
3-23
Fault Clear Mode
241
Faults
3-23
Fault Clr Mask
283
Masks & Owners
Fault Clr Owner
295
Masks & Owners
Fault Config 1
238
Faults
3-23
Fault Frequency
224
Diagnostics
3-22
Fault Speed
224
Diagnostics
3-22
Feedback Select
80
Spd Mode & Limits
3-10
Flux Current
5
Metering
3-6
Flux Current Ref
63
Torq Attributes
Flux Up Mode
57
Torq Attributes
Flux Up Time
58
Torq Attributes
Flying Start En
169
Restart Modes
Flying StartGain
170
Restart Modes
IR Voltage Drop
62
Torq Attributes
Ixo Voltage Drop
64
Torq Attributes
Jog Mask
278
Masks & Owners
Jog Owner
290
Masks & Owners
Jog Speed
100
Discrete Speeds
3-12
Jog Speed 1
100
Discrete Speeds
3-12
Language
201
Drive Memory
3-20
Last Stop Source
215
Diagnostics
3-21
Load Frm Usr Set
198
Drive Memory
3-19
Local Mask
285
Masks & Owners
Local Owner
297
Masks & Owners
Logic Mask
276
Masks & Owners
Man Ref Preload
193
HIM Ref Config
3-19
Maximum Freq
55
Torq Attributes
Maximum Speed
82
Spd Mode & Limits
3-10
Maximum Voltage
54
Torq Attributes
Minimum Speed
81
Spd Mode & Limits
3-10
MOP Frequency
11
Metering
3-6
MOP Mask
284
Masks & Owners
MOP Owner
296
Masks & Owners
MOP Rate
195
MOP Config
3-19
MOP Reference
11
Metering
3-6
Motor Cntl Sel
53
Torq Attributes
Motor NP FLA
42
Motor Data
Motor NP Hertz
43
Motor Data
Motor NP Power
45
Motor Data
Motor NP RPM
44
Motor Data
Motor NP Volts
41
Motor Data
Motor OL Count
220
Diagnostics
3-22
Motor OL Factor
48
Motor Data
Motor OL Hertz
47
Motor Data
Motor Type
40
Motor Data
Mtr NP Pwr Units
46
Motor Data
Output Current
3
Metering
3-6
Output Freq
1
Metering
3-6
Output Power
7
Metering
3-6
Output Powr Fctr
8
Metering
3-6
Output Voltage
6
Metering
3-6
Overspeed Limit
83
Spd Mode & Limits
3-10
Param Access Lvl
196
Drive Memory
3-19
PI Configuration
124
Process PI
3-13
PI Control
125
Process PI
3-13
PI Error Meter
137
Process PI
3-14
PI Fdback Meter
136
Process PI
3-14
PI Feedback Sel
128
Process PI
3-13
PI Integral Time
129
Process PI
3-13
PI Lower Limit
131
Process PI
3-13
PI Output Meter
138
Process PI
3-14
Parameter Name
Number
Group
Page
PI Preload
133
Process PI
3-14
PI Prop Gain
130
Process PI
3-13
PI Ref Meter
135
Process PI
3-14
PI Reference Sel
126
Process PI
3-13
PI Setpoint
127
Process PI
3-13
PI Status
134
Process PI
3-14
PI Upper Limit
132
Process PI
3-13
Power Loss Level
186
Power Loss
Power Loss Mode
184
Power Loss
Power Loss Time
185
Power Loss
Power Up Marker
242
Faults
3-23
Preset Speed X
101-107
Discrete Speeds
3-12
PWM Frequency
151
Load Limits
Rated Amps
28
Drive Data
3-6
Rated kW
26
Drive Data
3-6
Rated Volts
27
Drive Data
3-6
Reference Mask
280
Masks & Owners
Reference Owner
292
Masks & Owners
Reset Meters
200
Drive Memory
3-20
Reset To Defalts
197
Drive Memory
3-19
Run Boost
70
Volts per Hertz
S Curve %
146
Ramp Rates
Save HIM Ref
192
HIM Ref Config
3-19
Save MOP Ref
194
MOP Config
3-19
Save To User Set
199
Drive Memory
3-19
Skip Freq Band
87
Spd Mode & Limits
3-10
Skip Frequency X
84-86
Spd Mode & Limits
3-10
Sleep Level
182
Restart Modes
Sleep Time
183
Restart Modes
Sleep-Wake Mode
178
Restart Modes
Sleep-Wake Ref
179
Restart Modes
Slip Comp Gain
122
Slip Comp
3-12
Slip RPM @ FLA
121
Slip Comp
3-12
Slip RPM Meter
123
Slip Comp
3-12
Speed Mode
80
Spd Mode & Limits
3-10
Speed Ref Source
213
Diagnostics
3-21
Speed Ref X Hi
91, 94
Speed Reference
3-11
Speed Ref X Lo
92, 95
Speed Reference
3-11
Speed Ref X Sel
90, 93
Speed Reference
3-11
Start At PowerUp
168
Restart Modes
Start Inhibits
214
Diagnostics
3-21
Start Mask
277
Masks & Owners
Start Owner
289
Masks & Owners
Start/Acc Boost
69
Volts per Hertz
Status X @ Fault
227, 228
Diagnostics
3-22
Stop Mode X
155, 156
Stop/Brake Modes
Stop Owner
288
Masks & Owners
Stop/BRK Mode X
155, 156
Stop/Brake Modes
SV Boost Filter
59
Torq Attributes
TB Man Ref Hi
97
Speed Reference
3-11
TB Man Ref Lo
98
Speed Reference
3-11
TB Man Ref Sel
96
Speed Reference
3-11
Testpoint X Data
235, 237
Diagnostics
3-23
Testpoint X Sel
234, 236
Diagnostics
3-23
Torque Current
4
Metering
3-6
Torque Perf Mode
53
Torq Attributes
Trim Hi
119
Speed Trim
3-12
Trim In Select
117
Speed Trim
3-12
Trim Lo
120
Speed Trim
3-12
Trim Out Select
118
Speed Trim
3-12
Voltage Class
202
Drive Memory
3-20
Wake Level
180
Restart Modes
Wake Time
181
Restart Modes
Parameter Name
Number
Group