Rockwell Automation 20M LPM15 Liquid-Cooled Adjustable Frequency AC Drive FRN 2.xxx User Manual
Page 75

Programming and Parameters
3-27
C
O
MMUNICA
TIO
N
Da
ta
links
300
301
[Data In A1] - Link A Word 1
[Data In A2] - Link A Word 2
Parameter number whose value will be written from a communications
device data table.
Parameters that can only be changed while drive is stopped cannot be
used as Datalink inputs. Entering a parameter of this type will “Disable”
the link.
Default:
Min/Max:
Units:
0 (0 = “Disabled”)
0/387
1
302
303
[Data In B1] - Link B Word 1
[Data In B2] - Link B Word 2
See
[Data In A1] - Link A Word 1 [Data In A2] -
304
305
[Data In C1] - Link C Word 1
[Data In C2] - Link C Word 2
See
[Data In A1] - Link A Word 1 [Data In A2] -
306
307
[Data In D1] - Link D Word 1
[Data In D2] - Link D Word 2
See
[Data In A1] - Link A Word 1 [Data In A2] -
310
311
[Data Out A1] - Link A Word 1
[Data Out A2] - Link A Word 2
Parameter number whose value will be written to a communications
device data table.
Default:
Min/Max:
Units:
0 (0 = “Disabled”)
0/387
1
312
313
[Data Out B1] - Link B Word 1
[Data Out B2] - Link B Word 2
See
[Data Out A1] - Link A Word 1 [Data Out A2] -
314
315
[Data Out C1] - Link C Word 1
[Data Out C2] - Link C Word 2
See
[Data Out A1] - Link A Word 1 [Data Out A2] -
316
317
[Data Out D1] - Link D Word 1
[Data Out D2] - Link D Word 2
See
[Data Out A1] - Link A Word 1 [Data Out A2] -
Fil
e
Gr
oup
No.
Parameter Name & Description
See
page 3-2
for symbol descriptions
Values
Related