Specifications, A-2 supplemental drive information – Rockwell Automation 22F PowerFlex 4M User Manual FRN 1.xx - 2.xx User Manual
Page 82
A-2
Supplemental Drive Information
PowerFlex 4M Adjustable Frequency Drive FRN 1.xx - 2.xx User Manual
Publication 22F-UM001D-EN-E
Specifications
Drive Ratings
Catalog
Number
Output Ratings
Input Ratings
Branch Circuit Protection
kW (HP)
Amps
Voltage
Range
kVA
Amps Fuses
140M Motor
Protectors
(2)
(3)
Contactors
Min. Enclosure
Volume
(4)
(in.
3
)
100 - 120V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output
22F-V1P6N103
0.2 (0.25) 1.6
90-126
0.8
6.4
10
140M-C2E-C10
100-C09
1655
22F-V2P5N103
0.4 (0.5)
2.5
90-126
1.1
9.0
15
140M-C2E-C16
100-C12
1655
22F-V4P5N103
0.75 (1.0) 4.5
90-126
2.2
18.0
30
140M-D8E-C20
100-C23
1655
22F-V6P0N103
1.1 (1.5)
6.0
90-126
2.9
24.0
40
140M-F8E-C32
100-C30
1655
200 - 240V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output
22F-A1P6N103
0.2 (0.25) 1.6
180-265 0.7
5.3
10
140M-C2E-B63
100-C09
1655
22F-A2P5N103
0.4 (0.5)
2.5
180-265 1.6
6.5
10
140M-C2E-C10
100-C09
1655
22F-A4P2N103
0.75 (1.0) 4.2
180-265 2.0
8.2
15
140M-C2E-C16
100-C12
1655
22F-A8P0N103
1.5 (2.0)
8.0
180-265 5.4
22.3
35
140M-D8E-C25
100-C23
1655
22F-A011N103
2.2 (3.0)
11.0
180-265 5.9
24.3
40
140M-F8E-C32
100-C30
1655
200 - 240V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output, with Filter
22F-A1P6N113
0.2 (0.25) 1.6
180-265 1.3
5.3
10
140M-C2E-B63
100-C09
1655
22F-A2P5N113
0.4 (0.5)
2.5
180-265 1.6
6.5
10
140M-C2E-C10
100-C09
1655
22F-A4P2N113
0.75 (1.0) 4.2
180-265 2.0
8.2
15
140M-C2E-C16
100-C12
1655
22F-A8P0N113
1.5 (2.0)
8.0
180-265 5.4
22.3
35
140M-D8E-C25
100-C23
1655
22F-A011N113
2.2 (3.0)
11.0
180-265 5.9
24.3
40
140M-F8E-C32
100-C30
1655
200 - 240V AC (±10%) – 3-Phase Input, 0 - 230V 3-Phase Output
22F-B1P6N103
0.2 (0.25) 1.6
180-265 0.8
1.9
3
140M-C2E-B25
100-C09
1655
22F-B2P5N103
0.4 (0.5)
2.5
180-265 1.2
2.7
6
140M-C2E-B40
100-C09
1655
22F-B4P2N103
0.75 (1.0) 4.2
180-265 2.1
4.9
10
140M-C2E-B63
100-C09
1655
22F-B8P0N103
1.5 (2.0)
8.0
180-265 4.0
9.5
15
140M-C2E-C16
100-C12
1655
22F-B012N103
2.2 (3.0)
12.0
180-265 6.3
15.0
25
140M-C2E-C20
100-C23
1655
22F-B017N103
3.7 (5.0)
17.5
180-265 8.8
21.1
35
140M-F8E-C25
100-C23
1655
22F-B025N104
(1)
5.5 (7.5)
25.0
180-265 11.4
27.2
45
140M-F8E-C32
100-C37
3441
22F-B033N104
(1)
7.5 (10.0) 33.0
180-265 16.1
38.5
60
140M-F8E-C45
100-C60
3441
380 - 480V AC (±10%) – 3-Phase Input, 0 - 460V 3-Phase Output
22F-D1P5N103
0.4 (0.5)
1.5
340-528 1.5
1.8
3
140M-C2E-B25
100-C09
1655
22F-D2P5N103
0.75 (1.0) 2.5
340-528 3.0
3.5
6
140M-C2E-B40
100-C09
1655
22F-D4P2N103
1.5 (2.0)
4.2
340-528 5.0
6.0
10
140M-C2E-C10
100-C09
1655
22F-D6P0N103
2.2 (3.0)
6.0
340-528 5.2
6.2
10
140M-C2E-C10
100-C09
1655
22F-D8P7N103
3.7 (5.0)
8.7
340-528 7.0
8.3
15
140M-C2E-C16
100-C12
1655
22F-D013N104
(1)
5.5 (7.5)
13.0
340-528 12.9
15.4
25
140M-D8E-C20
100-C23
3441
22F-D018N104
(1)
7.5 (10.0) 18.0
340-528 16.3
19.5
30
140M-F8E-C25
100-C23
3441
22F-D024N104
(1)
11.0 (15.0) 24.0
340-528 21.7
26.1
40
140M-F8E-C32
100-C30
3441
380 - 480V AC (±10%) – 3-Phase Input, 0 - 460V 3-Phase Output, with Filter
22F-D1P5N113
0.4 (0.5)
1.5
340-528 1.5
1.8
3
140M-C2E-B25
100-C09
1655
22F-D2P5N113
0.75 (1.0) 2.5
340-528 3.0
3.5
6
140M-C2E-B40
100-C09
1655
22F-D4P2N113
1.5 (2.0)
4.2
340-528 5.0
6.0
10
140M-C2E-C10
100-C09
1655
22F-D6P0N113
2.2 (3.0)
6.0
340-528 5.2
6.2
10
140M-C2E-C10
100-C09
1655
22F-D8P7N113
3.7 (5.0)
8.7
340-528 7.0
8.3
15
140M-C2E-C16
100-C12
1655
22F-D013N114
(1)
5.5 (7.5)
13.0
340-528 12.9
15.4
25
140M-D8E-C20
100-C23
3441
22F-D018N114
(1)
7.5 (10.0) 18.0
340-528 16.3
19.5
30
140M-F8E-C25
100-C23
3441
22F-D024N114
(1)
11.0 (15.0) 24.0
340-528 21.7
26.1
40
140M-F8E-C32
100-C30
3441
(1)
Catalog suffix ending with ‘4’, such as N104 and N114, indicate that an internal brake IGBT is supplied.
(2)
The AIC ratings of the Bulletin 140M Motor Protector Circuit Breakers may vary. See
(3)
Manual Self-Protected (Type E) Combination Motor Controller, UL listed for 208 Wye or Delta, 240 Wye or Delta, 480Y/
277 or 600Y/347. Not UL listed for use on 480V or 600V Delta/Delta, corner ground, or high-resistance ground systems.