beautypg.com

Connector pin assignments – Rockwell Automation 48MS MultiSight Vision Sensor User Manual

Page 66

background image

MultiSight™ User Manual

Maintenance

66

10000000877(02)

Connector Pin Assignments

PWR and I/O connector

 Indicates sensor evaluation is valid for OUT1 and OUT2, except in special cases noted in the Configurable

Delays section on page 40.

 Control Input IN2: if the Control Input parameter (Detector Parameter window) is set to Enable (default

setting), the control input IN2 must be connected to V+ (24V DC) for the sensor to operate. If the control
input IN2 is not connected to V+, the MultiSight will not execute evaluations if the trigger mode is set to
“triggered” (standby mode) (see page “Use of Control Input IN2” on page 58).

Ethernet M12 D-Code 4-Pin Connector

Pin (M12)

Color

Use

1

White

IN1 (external trigger)

2

Brown

24V DC (V+)

3

Green

OUT1 (pass/fail); display LED = Q1

4

Yellow

OUT4 (ready) 

5

Grey

IN2 (control input) 

6

Pink

OUT3 (external illumination trigger)

7

Blue

GND (V-)

8

Red

OUT2 (position); display LED = Q2

Pin (M12 D-Code)

Use

1

Tx+

2

Rx+

3

Tx-

4

Rx-

E