Start-up

44

10000000877(02)

Screen Shot

Field name

Description

Display: ROI, Pattern, and
Position

For currently non-selected detectors whose Display
Icon check box is selected, the check boxes determine
whether each respective frame is displayed on the
image.

Single Image
(via Trigger)

Allows the user to capture a single image initiated by
the external (or software) trigger, including trigger
delay parameter settings. This allows the user to
capture an image for teaching without stopping the
production line. This also can be used to identify the
ideal trigger delay setting.

Redraw (Brightness
detector type only)

When using the brightness detector type, the image
will color all of the “dark” (or “light”) pixels blue (or
other selected color).

Region of Interest (yellow frame with detector #) should always fully
surround the pattern to be detected. It defines the maximum search
area in which the pattern will be recognized.

Pattern (red frame)
Defines the pattern or contour to be taught. During the inspection
process the pattern frame does not have any function other than to
mark the original location of the taught pattern. The green match
frame indicates where the pattern was detected.

Position frame (blue)
The Position Control (OUT2) determines whether the detected
pattern’s center is within this frame.