beautypg.com

Rockwell Automation 48MS MultiSight Vision Sensor User Manual

Page 40

background image

MultiSight™ User Manual

Start-up

40

10000000877(02)

Configurable Delays

There are three timing mechanisms that can be used: Trigger Delay, Output Delay, and Output Duration. Each has a range of
0…3000 ms. The following timing diagrams show the behavior of the outputs for each timing mechanism condition.

Case 1: No delay timers used (default state)

Case 2) Trigger Delay = Time (in ms) between the Trigger Input turning on (rising edge) and the image exposure

IN1

(Trigger)

Evaluation Time of Sensor

Ready On

"

Ouput Valid

OUT4

(Ready/Busy)

OUT 1+2

(Pass/Fail)

IN1

(Trigger)

Evaluation
Time

Trigger
Delay

Ready On

"

Ouput Valid

OUT4

(Ready/Busy)

OUT 1+2

(Pass/Fail)