Start-up

28

10000000877(02)

Parameter

Description

Screen Shot

Logic

The Logic field allows the user to define how the detectors are
linked together to determine the single OUT1 (pass/fail) output. A
detector can be standalone (inspection of a single characteristic),
logically linked (multiple inspections on a single part), or grouped
(multiple inspections on different parts). (The concept is more
thoroughly described in the above general description of the Select
Detector window.) The state of the inspection output OUT1
(passes/fails)/LED Q1 is determined by how the individual detector
evaluation results are linked in the Logic field.

The evaluation of logically linked detectors is
based on a single image. This means that
certain detector parameters must be the
same for all detectors that are logically
linked together (see the chart below). The
recommended procedure is to set the first
detector in the group to the desired settings,
then use the Copy command in the
Commands window (on the left of the
software screen, see page 24) to copy the
configuration of that detector to the other
detectors that will be logically linked.

The software will give the error message
“group parameter check failed” when the
sensor is put into run mode if detectors that
are linked together have nonmatching
parameters that should match.

IMPORTANT