beautypg.com

Rockwell Automation 48MS MultiSight Vision Sensor User Manual

Page 46

background image

MultiSight™ User Manual

Start-up

46

10000000877(02)

Position Deviation Check and Frame Type

Position control can be activated when the pattern matching or contour matching detector types are selected. If position control is
selected, a blue frame is displayed on image screen. The X/Y coordinates for the center of the pattern detected (green cross at the
center of the green frame) with reference to the top left-hand corner of the image (zero point) is displayed in the result window. The
increment for X/Y coordinate values while using Detector Type Pattern Matching is 2 pixels so only even coordinate values will occur.
The center of the detected green pattern area (green cross) is inside the blue frame for correctly positioned parts. In Run mode, this
will activate the position output OUT2.

The center of the detected pattern (indicated by the green cross
in the green frame) is within the blue position frame. Position
output OUT2 would be active.

Pattern

Region of

Interest

Sensor Image

Pattern

Region of

Interest

Sensor Image

Faster

Slower

X

Y