Start-up

10000000877(02)

21

11.

If no live image appears, check to confirm the following:
a.

No obstruction in front of the lens.

b.

Sufficient lighting. Detector Parameter “Illumination” should be “Internal ON” or sufficient external lighting provided.

c.

Correct shutter settings (under Detector Parameters—see screen shot). Increase shutter time to brighten the image.

d.

Correct focus—focus screw on back of MultiSight.

5.

Adjusting image focus: To adjust image definition, turn the focusing screw on the back of the housing (see the illustration in
“Electrical Installation” on page 8) in clockwise direction (increase the focusing distance) or counterclockwise direction
(decrease the focusing distance). Check the position of the MultiSight and adjust if necessary.

The basic setup of the MultiSight is complete. To differentiate between “GOOD” and “BAD” parts, use the software to configure the
MultiSight. The next section describes the configuration software.

Make fine adjustments to shutter speed and focus using “GOOD”
parts to enable optimal configuration.

IMPORTANT