Parameter

Description

Screen Shot

Sensor name

Assign a name for the connected MultiSight. This name appears in
the MultiSight Sensor Finder software and allows for easier
identification of the correct sensor when multiple MultiSight
sensors are on a single network.

Live Images

When this checkbox is selected, the live image is displayed in the
Image window of the software during Run mode.

Selecting this mode increases evaluation
cycle time (whether the sensor is connected
to the software or not). Deselect this option
for the faster evaluation time.

Recorder

Off

 No images are recorded on the sensor

Failed images

 The MultiSight records up to the last 30 images

of evaluations that FAIL

All images

 The MultiSight records up to the last 30 images

(both PASS and FAIL)

See Commands/Recorder Images on page 24 for instructions on
transferring the images from the MultiSight to the computer