Rockwell Automation 48MS MultiSight Vision Sensor User Manual
Page 30
MultiSight™ User Manual
Start-up
30
10000000877(02)
Parameter
Description
Screen Shot
Logic (continued)
In order to use the grouping functionality,
Detector Parameter Control Input must be
set to “Activate 0
31” for ALL active
detectors.
The same Logic is applied to each Group of
detectors. Example: if the detectors in Group
A are logically linked with AND, the detectors
in Group B will be logically linked with AND.
It is not possible to link Group A with AND
and Group B with OR.
It is not possible to logically link groups with one another.
The functionality of the left-hand check box is different for
grouping than for the logical linking previously described. The
evaluation of a group begins with the detector last selected via the
Control Input (IN2). (When the sensor is connected to the
computer for configuration, the radio button currently selected will
determine which detector the sensor begins the group evaluation
with.) The sensor evaluates each detector that has a check in the
left hand box. The next detector that does NOT have a check is the
last detector in the group. If detectors 1-3 have a check and 4 does
not, Group A is detectors 1-4. See the screen shot to the right.
The detectors in different groups do not have to have matching
parameters; however, those within the same group must follow
the matching parameter guidelines listed above.
IMPORTANT
}
}
Group A
Group B