Maintenance

10000000877(02)

65

Connection: M12 (Micro) 8-pin Male QD (both PWR and I/O and ethernet)

Ethernet connection: M12 (micro) 4-pin D-code female quick disconnect (ethernet connection, EtherNet/IP model).

Power and I/O Connection Cable Wiring Diagram

5

6

7

8

4

3

1

2

E

3

2

1

4

P ass/ Fail

Position

Ready

PLC

Input

(I/O)

Control

V+ or

PLC

Output

White (1)

Green (3)

Br own (2)

Blue (7)

Pink (6)

Red (8)

Yellow (4)

Gr ey (5)

V+

(24V DC)

V-

(GND)

Not

Connected

Trigger
Sensor

48MS

Inspection Target

Trigger Sensor

PNP Output