Appendix A: Weekly Testing Procedure

109

appendIx a: weekly
testIng proCedure

We recommend that you test your Sensaphone weekly to be sure it is

functioning properly. This will ensure that when a problem arises the

Sensaphone will be ready to alert the appropriate personnel.
There are several tests that can be performed:
1) Call the unit and listen to the Status Report. This will test the unit’s abil-

ity to answer the phone and speak a message. It will also verify that all of

the zones are reading properly, the alarm conditions are OK, the electric-

ity is on, the microphone is functioning, and the batteries are OK.

2) Create an alarm on each zone by tripping all connected sensors.

Temperature sensors: Heat or cool the sensor.

Motion sensors: Have someone walk in front of the sensor.

Door/window sensors: open the door/window.