106
SENSAPHONE 400 User’s Manual
Keypad commands:
1) To enable Vacation Mode, press the [SENSOR ON/OFF] key, then the
[OUTPUT] key. The unit will respond by saying “ON” to indicate that
Vacation Mode is set. The Suitcase icon
will appear and blink on the
thermostat LCD.
2) To enable Normal Mode, press the [SENSOR ON/OFF] key, then the
[OUTPUT] key. The unit will respond by saying “OFF” to indicate that
Normal Mode is set. The Sun
or Moon icon will appear on the
thermostat LCD.
TouchTone Commands:
Call the Sensaphone. When the unit answers, it will begin reciting a sta-
tus report. At any time during the call, press a Touch-Tone. The unit will
respond with “OK.” The Sensaphone is now ready to accept Touch-Tone
commands.
1) To enable Vacation Mode, press SRO (776). The unit will respond by
saying “ON” to indicate that Vacation Mode is set. The Suitcase icon
will appear and blink on the thermostat LCD.
2) To enable Normal Mode, press SRO (776). The unit will respond by
saying “OFF” to indicate that Normal Mode is set. The Sun
or Moon
icon will appear on the thermostat LCD.
3) To check the status of the ouput press WRO (976). The unit will respond
“OFF” for Normal Mode or “ON” for Vacation Mode.
4) Hang up.
8 .3 .2 dual thermoStat Control
When a three or four wire low voltage thermostat is used, it is easy to con-
nect the Sensaphone to your furnace with the addition of a secondary ther-
mostat. One thermostat is set to your preferred “away” temperature and the
other thermostat is set to your preferred “home” temperature. With your
Sensaphone 400, you will be able to switch between these two thermostats
using the relay output.
Ideally, the “away” thermostat would be in your pump or furnace room.
Remember that your “away” thermostat will be the only thermostat that
keeps your cottage or cabin at minimal heat while you are away. It should