Included in package, Suggested optional equipment, Specifications – SDC 1511T EXIT CHECK DELAYED EGRESS EMLOCK User Manual
Page 3
Included in Package
1511S EMLOCK
HOUSING ASSY. &
MOUNTING PLATE
728
Single station two
function key switch
control for alarm
reset and access or
sustained bypass.
918 Digital Keypad
Two relay outputs:
Relay 1 -Reset;
Relay 2 – Choice of
momentary or
sustained bypass.
101-4AM
Provides visual &
audible annunciation
with audible mute for
one, two, three or
four openings.
728-L
Single station two
function key switch
control for alarm reset
and access with a tri-
colored LED showing
door condition.
702-R
Single station one
function key switch
control for alarm
reset.
101-1A
The single station
annunciator is
equipped with a tri-
colored LED and
audible alarm.
101-1AK
Visual & audible
annunciation and a
two function key
switch for alarm reset
and access or
sustained bypass.
101-PAM
Visual & audible
annunciation, timed
access, sustained
bypass and audible
mute.
SDC Annunciator Consoles
provide remote annunciation
of multiple openings. Stations
are specified in sets of four.
Control switches are capable
of both sustained bypass and
timed unlocking.
TCC Desk Top :
Stations 4, 8, & 12
Suggested Optional Equipment
Digital Entry
Station Controls, Annunciator Panels, and Consoles
P:\INSTALLATION INST\Delayed Egress\INST-1511ST\INST-1511ST.vsd Rev G3 10-13 Page 3
PSB560
Request-to-exit pressure
sense non-latching bar
that will activate the Exit
Check
®
when slight
pressure is applied to
the bar. For doors
without latching.
Remote Speaker
101-SP
Indoor Surface Mount;
85dB@3ft.;
Compact Design (4 in. sq.);
Plug-in connector included
for easy installation
Specifications
Interior Applications Only
Input Voltage Requirements:
Dual Voltage (Auto Sensing) –
12/24 VDC (+/- 10%)
(Use with a UL 294 Standard Power Supply)
Power Consumption:
Standard Model (1650 lbs.) -
1511S – 820/500 mA@ 12/24 VDC
1511T – 1500/850 mA @ 12/24 VDC
Energy Saver (1200 lbs., “E” Option) –
1511S – 452/274 mA@ 12/24 VDC
1511T – 660/486 mA @ 12/24 VDC
Size: 11"L x 2-3/4"H x 2-5/8"D
Lock Status Relay Rating: 1 Amp @ 30V resistive
Alarm Output Rating: 1 Amp @ 30V resistive
DPS Rating: 250 mA @ 30V resistive
BAS Rating: 250 mA @ 30V resistive
ATS Rating: 1 Amp @ 30V resistive
Operating Condition: 0-49 deg C, 85% RH
(non-condensing)
1511S ARMATURE
1511S-12T
TEMPLATE
TEMP-1511
1/2” DIA FOR WIRE
First install mounting plate at two slot locations only and make proper
adjustments before marking remaining five mounting hole locations.
FOLD ON DOTED LINE
Mark location five places:
#10 self dril/tap screws provided for up to 1/8” thick metal applications.
Note: Machine screws provided for applications with heavier
gauge material – Drill (#21) and tap for #10-32 screw.
PLACE AGAINST LOCK JAMB FOR L.H. DOORS
1/4” DIA GUIDE PIN HOLE 9/16” DEEP
PLACE AGAINST
LOCK JAMB FOR
R.H. DOORS
PLACE AGAINST DOOR
Center punch on mark
ARMATURE
SCREW PACK
1580S-101-C
1511S TRIGGER &
ARMATURE BASE
1511S-11
Power Supply
600 Series Power Supply
Field Selectable 12 or 24VDC modular
Power Supplies with Fire/Life Safety
Emergency Release. Tri-colored LED,
separate PTC protected outputs, battery
charger, and Class 2 Outputs.
602RF 1 Amp
631RF 1.5 Amp
632RF 2 Amp
634RF 4 Amp
636RF 6 Amp
EMLOCK
SCREW PACK
C-1500