Dip switch settings by model option code – SDC 1511T EXIT CHECK DELAYED EGRESS EMLOCK User Manual
Page 11
Dip Switch Settings By Model Option Code
P:\INSTALLATION INST\Delayed Egress\INST-1511ST\INST-1511ST.vsd Rev G3 10-13 Page 11
1
off
ON
BH
30 sec
30 sec
Switch
2
off
ON
0 sec
1 sec
Switch
3
ON
off
1 sec
15 sec
Switches
4
ON
off
ON
off
20 sec
30 sec
off
ON
5
off
ON
Internal
Remote
Switch
6
off
ON
Unlocked
Locked
Switch
7
off
ON
Tone Only
Tone/Voice
Switch
8
ON
Msg #2
Msg #1
Switch
off
Option
BOCA compliant. Automatic alarm reset after
30 continuous seconds of door closure
1
off
ON
NH
30 sec
30 sec
Switch
2
off
ON
0 sec
1 sec
Switch
3
ON
off
1 sec
15 sec
Switches
4
ON
off
ON
off
20 sec
30 sec
off
ON
5
off
ON
Internal
Remote
Switch
6
off
ON
Unlocked
Locked
Switch
7
off
ON
Tone Only
Tone/Voice
Switch
8
ON
Msg #2
Msg #1
Switch
off
Option
NFPA compliant.
1
off
ON
BC
15 sec
15 sec
Switch
2
off
ON
0 sec
0 sec
Switch
3
ON
off
1 sec
15 sec
Switches
4
ON
off
ON
off
20 sec
30 sec
off
ON
5
off
ON
Internal
Remote
Switch
6
off
ON
Unlocked
Locked
Switch
7
off
ON
Tone Only
Tone/Voice
Switch
8
ON
Msg #2
Msg #1
Switch
off
Option
BOCA/Chicago compliant. 0 sec nuisance.
Automatic alarm reset after 30 continuous
seconds of door closure
1
off
ON
BD
15 sec
15 sec
Switch
2
off
ON
0 sec
1 sec
Switch
3
ON
off
1 sec
15 sec
Switches
4
ON
off
ON
off
20 sec
30 sec
off
ON
5
off
ON
Internal
Remote
Switch
6
off
ON
Unlocked
Locked
Switch
7
off
ON
Tone Only
Tone/Voice
Switch
8
ON
Msg #2
Msg #1
Switch
off
Option
BOCA compliant. Automatic alarm reset after 30
continuous seconds of door closure
1
off
ON
NC
15 sec
15 sec
Switch
2
off
ON
1 sec
2 sec
Switch
3
ON
off
1 sec
15 sec
Switches
4
ON
off
ON
off
20 sec
30 sec
off
ON
5
off
ON
Internal
Remote
Switch
6
off
ON
Unlocked
Unlocked
Switch
7
off
ON
Tone Only
Tone/Voice
Switch
8
ON
Msg #2
Msg #1
Switch
off
Option
NFPA/OSHPD compliant. Power Up
Unlocked and Manual Reset are fixed.
1
off
ON
ND
15 sec
15 sec
Switch
2
off
ON
1 sec
2 sec
Switch
3
ON
off
1 sec
15 sec
Switches
4
ON
off
ON
off
20 sec
30 sec
off
ON
5
off
ON
Internal
Remote
Switch
6
off
ON
Unlocked
Locked
Switch
7
off
ON
Tone Only
Tone/Voice
Switch
8
ON
Msg #2
Msg #1
Switch
off
Option
NFPA Compliant
RELEASE
TIME
NUSIANCE
DELAY
REQUEST TO EXIT
PERIOD
TRIGGER
TYPE
MESSAGE
TYPE
ALARM
TYPE
1
off
ON
NA
15 sec
30 sec
Switch
2
off
ON
1 sec
2 sec
Switch
3
ON
off
1 sec
15 sec
Switches
4
ON
off
ON
off
20 sec
30 sec
off
ON
5
off
ON
Internal
Remote
Switch
POWER UP
STATE
6
off
ON
Unlocked
Locked
Switch
7
off
ON
Tone Only
Tone/Voice
Switch
8
ON
Msg #2
Msg #1
Switch
off
Option
All options are selectable
RELEASE
NUISANCE
REQ TO EXIT
TRIG TYPE
POWER-UP
TONE-VOICE
MESSAGE
SWITCH
LOCATIONS
2
1
7
6
5
4
3
8
ON
O N
O F F
SWITCH
POSITIONS
J 7
J u m p e r
I n s t a l l e d
J u m p e r
R e m o v e d
J7
POSITIONS
(Door Prop Alarm Active)
(Door Prop Alarm Inactive)
J 7