beautypg.com

Diaphragm flexure installation, Aligning force train components – MTS Series 215 Rotary Actuator User Manual

Page 34

background image

Series 215 Rotary Actuator Product Manual

34

Diaphragm Flexure Installation

Installation

Diaphragm Flexure Installation

Depending upon user requirements, the end of the actuator rotor shaft can extend
beyond the flange, be flush with it, or be recessed into the flange adapter to allow
the use of the inside diameter as a pilot diameter.

Diaphragm flexures are used to reduce the potentially damaging effects of large
axial and lateral deflections of the actuator rotor shaft. Perform the necessary
calculations for determining whether or not diaphragm flexures are required by
the specific test system.

Mount the flexure(s) to either the flange adapter or the torque cell.

The following table lists the flexure ratings and mounting bolt torques for the
available flexure diaphragms.

Aligning Force Train Components

After the actuator, reaction bracket, and torque cell have been positioned on the
base plate or T-slot table, they must be aligned. The goal of the alignment process
is to ensure that the actuator and torque cell share the same centerline.

If the test system utilizes a base plate supplied by MTS, the actuator and reaction
bracket will have been pre-aligned at the factory. The combination of an MTS
base plate and reaction bracket enables the operator to easily move the reaction
bracket/torque cell assembly and simplifies the alignment procedure.

If the test system does not utilize an MTS base plate or T-slot table, the torque
cell has been separated from the reaction bracket, or the actuator has been moved,
then the “Component Centerline Alignment Procedure” must be performed in
order to ensure proper alignment of the components of the test system. If the
reaction bracket, torque cell, and actuator have not been moved and were
properly aligned when installed, then it is not necessary to perform the alignment
procedures.

The diaphragm flexure assemblies are self-centering.

Flange Adapter and Diaphragm Flexure Rating

M

ODEL

F

LANGE

AND

D

IAPHRAGM

F

LEXURE

R

ATING

M

OUNTING

B

OLT

T

ORQUE

LBF

·

N

.

M

LBF

·

IN

.

M

215.32

2000

226

18

24

215.35

5000

565

35

47

215.41

10,000

1130

35

47

215.42

20,000

2260

170

230

215.45

50,000

5650

170

230

215.51

100,000

11,300

280

380