2111 interbus fieldbus module, Appendix code table – Lenze EMF2111IB User Manual
Page 83
Appendix
Code table
5
2111 INTERBUS fieldbus module
5.8
5.8.1
L
5.8-3
EDSIBS-1.0-06/2003
5.8.1.3
Code table for the DRIVECOM profile 21
Explanation of the following code tables:
Name
Meaning
R/W
Write/read authorization via LECOM
Ra =
only read access permitted
Ra/W = Read access always permitted, write access permitted under certain conditions (e.g.
depending on Lenze parameter L-C0001 (operating mode) or controller status)
PD
Mapping to INTERBUS process data (index 6010
hex
, 6011
hex
)
PI =
Process input data (from the controller to the host)
PO =
Process output data (from the host to the controller)
POI =
Process input and output data (see PO and PI)
- =
Mapping of the process data not possible
SP
Non-voltatile saving of the parameter
y =
Yes
Parameter will be saved
n =
No
Parameter will not be saved
- =
Parameter depends on the process and will therefore not be saved
Data str.
Data structure
S =
Simple variable
The parameter consists of one value and can only be addressed via subindex 0.
A =
Array variable (field parameter)
The parameter contains several values of the same data type. The individual elements can
be directly addressed by means of the subindex. Subindex = 0 addresses the whole
parameter contents.
R =
Record variable (combined parameter)
The parameter contains several values of different data types. Subindex = 0 addresses the
whole parameter contents.
Data type
Data type
yp
BOL =
Boolean
FALSE = 00
hex
; TRUE = FF
hex
I8 =
Integer8
−128 ≤ x ≤ 127
I16 =
Integer16
−32768 ≤ x ≤ 32767
I32 =
Integer32
−2147483648 ≤ x ≤ 2147483647
U8 =
Unsigned8
0 ≤ x ≤ 255
U16 =
Unsigned16
0 ≤ x ≤ 65535
U32 =
Unsigned32
0 ≤ x ≤ 4294967295
OS =
Octet string 8 bit/byte [= 1 byte or 8 bit per byte] binary coded
VS =
Visible string; text coded to ISO 646
PDS =
Process data description structure (index 20
hex
)
RS =
Ramp structure (index 21
hex
)
Subindex 1: U32, numerator ”delta_speed“ in rev/min
Subindex 2: U16, denominator ”delta_time“ in seconds
Data number
Display of the parameter elements
Data length
Total length of the parameter in byte
Show/Hide Bookmarks