2111 interbus fieldbus module, Data transfer process data channel configuration – Lenze EMF2111IB User Manual
Page 27

Data transfer
Process data channel configuration
5
2111 INTERBUS fieldbus module
5.6
5.6.1
L
5.6-5
EDSIBS-1.0-06/2003
The parameter describes the process data which are sent from the controller to
the INTERBUS master (input data for the INTERBUS master). Parameters of the
described process data assignment of Lenze controllers can be assigned to the
subindex values (see
(
¶ 5.6-6)
). Exception: The value for subindex 1 cannot be
changed.
Ensure that the parameters of the process data channel are only used once, i.e.
double assigment must be avoided (example: DC speed and speed setpoint are
sent via AIF-W1).
Parameter name (Index)
Subindex
Data structure
Data type
PI data description (6000
hex
)
1 ... 13
R
PBS(20
hex
)
)
)
)
)
Note!
Only the valid subindex is displayed with the parameter 6000
hex
.
It is determined by PD!
Subindex
Meaning
Lenze setting
Notes
Meaning
Value
1
Number of process data [byte]
04
hex
2
Index
PI data word 1
6041
hex
DRIVECOM status word
3
Subindex
PI data word 1
00
4/5
No entry
00
6
Index
PI data word 2
6044
hex
DRIVECOM speed
7
Subindex
PI data word 2
00
8/9
No entry
00
10
Index
PI data word 3
5CA5
hex
AIF-OUT.W2
Of if code
C
11
Subindex
PI data word 3
03
L-C1910 = 6
12/13
No entry
00
The parameter describes the process data which are sent to the controller from
the INTERBUS master (output data for the INTERBUS master). Parameters of the
described process data of Lenze controllers can be assigned to subindex values
(see
(
¶ 5.6-6)
). Exception: The value for subindex 1 cannot be changed.
Ensure that the parameters of the process data channel are only used once, i.e.
double assigment must be avoided (example: DC speed and speed setpoint are
sent via AIF-W1).
Parameter name (Index)
Subindex
Data structure
Data type
PO data description (6001
hex
)
1 ... 13
R
PBS(20
hex
)
Subindex
Meaning
Lenze setting
index
/
Notes
g
Value
6002 / Bit
1
Number of process data
[byte]
04
hex
2
Index
PO data word 1
6040
hex
DRIVECOM control word
0
3
Subindex
PO data word 1
00
4/5
No entry
00
1
6
Index
PO data word 2
6042
hex
DRIVECOM speed setpoint
2
7
Subindex
PO data word 2
00
8/9
No entry
00
3
10
Index
PO data word 3
5CA7
hex
AIF-IN.W2
4
Only if
C
11
Subindex
PO data word 3
03
hex
y
L-C1910 = 6
12/13
No entry
00
5
PI data description (6000
hex
)
9
PO data description (6001
hex
)
10
Show/Hide Bookmarks