2111 interbus fieldbus module, 8 appendix – Lenze EMF2111IB User Manual
Page 81
Appendix
Code table
5
2111 INTERBUS fieldbus module
5.8
5.8.1
L
5.8-1
EDSIBS-1.0-06/2003
5.8
Appendix
5.8.1
Code table
5.8.1.1
Codes of the 2111 INTERBUS fieldbus module
These codes determine the software used.
Software version and date can be read.
Code
Values
Lenze setting
Explanation
L-C1810 33S2111I_xy000
Software registration number of 2111
L-C1811
Software creation date [mmm tt jjjj hh:mm:ss]
Here you can enter the number of transferred process data words in bytes.
The number of process data can have up to 6 bytes. L-C1910 can be written with
the values 4 and 6. The value is saved in the EEPROM of the 2113 fieldbus module.
A change of process data length only becomes effective after a basic initialisation
of the fieldbus module, i.e. after switching off the supply voltage.
A value higher than 4 bytes should only be used for 93XX and 8200 vector since
only here the data can be passed on. However, a length of > 4 bytes is possible
with 82XX.
Code
Values
Lenze setting
Explanation
L-C1910 4, 6
4
INTERBUS process data length in bytes
Here you can set the unit or DRIVECOM control if all DIP switches are “ OFF” . The
setting is only active then.
Code
Values
Lenze setting
Explanation
L-C1911 0/1
1
•
1:
The control word is transmitted from the INTERBUS master
to the controller via the DRIVECOM status machine.
•
0:
The AIF-CTRL control word is active.
Software codes
Process data length
Unit or DRIVECOM control