Appendix
Code table
5
2111 INTERBUS fieldbus module
5.8
5.8.1
L
5.8-2
EDSIBS-1.0-06/2003
5.8.1.2
Controller codes
Code
Values
Lenze setting
Explanation
L-C0001
Operating mode
0
1
2
3
Control source
Terminal
Terminal
Terminal
INTERBUS
Setpoint source
Terminal
8201BB
Terminal
INTERBUS
Parameter source
INTERBUS
INTERBUS
(operating module
INTERBUS
INTERBUS
L-C0009 Process data preconfiguration
)
Please see the notes in chapter 5.6.3
L-C0142
This parameter L-C0142 prevents the drive from uncontrolled
restarts after:
•
Mains switching
•
Internal fault
•
Internal message (with pulse inhibit) > 0.5 s
If the controller sets the status ”message” because of a failure
(e.g. short mains failure) and the fault remains active for
longer than 0.5 s, controller inhibit will be set automatically.
The parameter L-C0142 has the following function:
•
L-C0142 = 1:
The drives will restart automatically as soon as the error
has been eliminated.
•
L-C0142 = 0:
The controller remains inhibited and the drive cannot
restart even if the error has been eliminated.
– The drive restarts after a LOW-HIGH transition at one of
the inputs for ”controller inhibit” (CINH, e.g. at terminal
X5/28) wieder an
All codes are described in detail in the corresponding Operating Instructions.