2111 interbus fieldbus module – Lenze EMF2111IB User Manual
Page 72
![background image](/manuals/565909/72/background.png)
Data transfer
Configuration of the parameter data channel (PCP communication)
5
2111 INTERBUS fieldbus module
5.6
5.6.8
L
5.6-50
EDSIBS-1.0-06/2003
The PCP service ” Get-OV“ reads the object description for each parameter and
data type.
The PCP service ” Identify“ informs about the controller identification. The
controller returns the following parameters:
Name
Value
Meaning
Name of the manufacturer
”Lenze“ (as visible string)
Company name
Controller name
Visible string with 15
characters
Unit name for controller and bus-interface module
Controller version
Visible string with 15
characters
Software version of the controller
Controller name
The visible string consists of the following characters:
l
Characters 1 to 5: Name of the controller
(4 characters for the controller name plus 1 blank)
l
Characters 6 to 10: Name of the fieldbus module
(4 characters for the controller name plus 1 blank)
l
Characters 11 to 15: No name
(5 blanks)
If a fieldbus module is not available, the corresponding area will be filled with
blanks.
Example:
8200 vector controller with 2113 fieldbus module: ” 8212 2113“
sáëáÄäÉ лнкбеЦ
`зенкзддЙк е~гЙ
_~лбЕ мебн
`зенкзддЙк е~гЙ
cáÉäÇÄìë гзЗмдЙ
_д~ев
8
2
1
2
2
1
1
3
N
S
NN
NR
Controller version
The visible string consists of the following characters:
l
Characters 1 to 5: software version of the controller:
– 2 characters for the basic version
– 2 characters for the variant
– 1 character for the version of the variant
l
Characters 6 to 10: software version of the fieldbus module
– 2 characters for the basic version
– 2 characters for the variant
– 1 character for the version of the variant
l
Characters 11 to 15: No name
– 5 blanks
Get-OV
19
Identify
20
Show/Hide Bookmarks