beautypg.com

10 appendix, Electrical data – JUMO 701550 di 308 - Digital Indicator Operating Manual User Manual

Page 70

background image

10 Appendix

70

Electrical data

Supply voltage (switch-
mode PSU)

AC 110—240V -15/+10%, 48—63Hz

AC/DC 20—30V, 48—63Hz

Electrical safety

acc. to EN 61010, part 1

Overvoltage category III, pollution degree 2

Power consumption

max. 13VA

Data backup

EEPROM

Electrical connection

at the back via screw terminals,

conductor cross section up to max. 2.5mm

2

with core-end ferrule (length: 10mm)

Electromagnetic
compatibility

Interference emission
Interference immunity

EN 61326-1

Class B

meeting industrial requirements

Installation information on conductor cross-sections
and core-end ferrules

min.
cross-
section

max.
cross-
section

Min. length of
core-end
ferrule

Without
core-end ferrule

0.34mm

2

2.5mm

2

10mm
(stripped)

Core-end ferrule
without lip

0.25mm

2.5mm

2

10mm

Core end ferrule
with lip
up to 1.5mm2

0.25mm

2

1.5mm

2

10mm

Core end ferrule
with lip
above 1.5mm2

1.5mm

2

2.5mm

2

12mm

Twin ferrule with
lip

0.25mm

2

1.5mm

2

12mm