7 Configuration

58

Scroll time

SCROLL-t

0…255

Scroll mode change-over time in seconds;
0 = scroll mode inactive
255 = scroll mode stop

With the scroll mode active, keys

i

and

d

can be used to select the next or

the previous scroll parameter. If the scroll
mode was stopped, further actions are only
possible with this key.

Adjustment of the scroll parameters only
possible in the setup program:
-> Display/Operation -> Display > Scroll mode

The parameter names are shown in the lower
display.
Example:
INPUT1 = Channel name, analog input 1
MIN INP1 = Min. value, analog input 1
MAX INP1 = Max. value, analog input 1
HOLD1 = Hold value, analog input 1

Function key
„F“

F-KEY

0
1
2
3
4
5
6

no function
Apply hold value
Tare function
Reset tare function
Reset min.-max value
Scroll mode stop
LK acknowledgement

Keep the function key pressed for at least 2
seconds to ensure that the function will be
performed.

Level
inhibit

(Setup)

none

Configura-
tion level

Access to the configuration level can be
inhibited. The setting is independent of binary
function „Level inhibit“.

Setting in the setup program:
-> Display/Operation -> Operation

See also Chapter 5.3 „Level inhibit“.

Parameter

Value/

Selection

Description

Factory settings are shown bold.