SECTION 10: CONFIGURATION MODE
10.1 Entering The Configuration Mode
To enter the Configuration Mode from Base Mode:
1. Press the MODE key until ConfPar appears in the message display.
2. Press the SCROLL key to enter the Configuration Mode.
To return to Base Mode:
1. Press and hold the MODE key for 5 seconds. The instrument will cycle through its
power-up sequence and return to BASE mode.
The user may step through the Configuration Mode parameters using the SCROLL key.
For each parameter, the Message Display will show a legend identifying that parameter
and the lower main display will show the current setting of that parameter. The setting
may be adjusted using the UP/DOWN keys. As soon as the setting is changed, the
lower main display will flash, indicating that the new setting has yet to be confirmed.
When the setting is as required, it may be confirmed by pressing the PROF key,
whereupon the upper display will stop flashing.
NOTE:
Changes to certain Configuration Mode parameters (i.e. input range,
output use and type) will cause other mode parameters to be automatically set to
their default values. Items affected include Tune Mode, and Pretune and Auto
Tune Facilities. Until the Tune Mode settings have been verified by changing at
least one parameter, the upper main display will show decimal points to indicate
that the values are in their default condition.
Changes to Configuration Mode parameters will not be accepted until they have been
verified with the PROF key.