Atop Technology SE5416A User manual User Manual
Page 39

Atop Industrial Serial Device Server
SE5408A/SE5416A Series
User Manual V 1.0
39
and has no effect on the Transparent Mode. When TCP data is received (request) and
passed to Serial side, the device will wait for the set time before transferring another TCP
data if the Serial side did not receive any data (response).
Serial
Serial FIFO, By default, SE5416A Series has its FIFO function enabled to optimize its
serial performance. In some applications (particularly when the flow control is enabled), it
may deem necessary to disable the FIFO function to minimize the amount of data that is
transmitted through the serial interface after a flow off event is triggered to reduce the
possibility of overloading the buffer inside the serial device. Please note that disabling
this option on baud rates higher than 115200bps would reduce the data integrity
noticeably.
Serial Buffer, By default, SE5416A Series will empty its serial buffer when a new TCP
connection is established. This means that the TCP application will not receive buffered
serial data during a TCP link breakage. To keep the serial data when there is no TCP
connection and send out the buffered serial data immediately after a TCP connection is
established, disable this option.