5.4.2 COM Configuration: Advanced Settings
Click on the “Advanced Settings” button to open the dialog (Figure 5.16).
Figure 5.16
TCP
TCP Timeout, S
pecify the value in “TCP Timeout” to force SE5416A Series actively
close a TCP connection after some specific inactivity time (no packets). The default value
for it is 3600 seconds. Disabling this option means SE5416A Series would never actively
close an established connection.
Delimiters
Serial to Network Packet Delimiter, Packet delimiter is a way of packing data in the
serial communication. It is designed to keep packets in track. SE5416A Series provides
three types of delimiter: Time Delimiter, Maximum Bytes and Character Delimiter. Note
that the following delimiters (Interval, Max Byte and Character) are programmed in the
OR logic. Meaning that if any of the three conditions were met, SE5416A Series would