MANUAL MODE

This printer has no manual feed tray or multi-purpose tray. Therefore you
cannot feed special paper in the usual way. However this printer has a
special Manual Feed Mode with Tray 1 to accommodate non-standard
paper sizes. When “MANUAL MODE=ON” is selected or a manual feed
command is sent to the printer, the printer will wait for you to replace the
paper in Tray 1 with the paper for manual printing.

1. Press the ▲ or ▼ button to select the manual mode on or off.

2. Press the

Set

button to make the setting effective.


MEDIA TYPE

When you use anything other than ordinary plain paper (such as thick
bond paper, envelope, or transparency), the appropriate media type must
be selected in the media type mode to get the best print quality.

1. Press the

Set

button to enter the media type mode. The

display then shows the current setting with an asterisk.


2. Press the ▲ or ▼ button to select regular, thick paper or

transparency then press the

Set

button to make the setting

effective.

Note

Please do not forget to change the setting back to regular after you
have printed on your special media with the setting changed.

SMALL SIZE

This printer can detect the size of paper in the trays automatically. If there
is no paper loaded as specified by the user application, the printer
prompts the user to load the correct size paper by displaying “LOAD
PAPER XX SIZE” on the LCD panel. The printer can detect A4, Letter,
Executive, Legal (only in Optional Legal Cassette) and B5(ISO), but not
A5, B5(JIS), COM10 and DL size even though they can be handled.
For this reason, it is necessary to change the detection size for paper
smaller than B5.

1. Press the

Set

button to enter the small size mode. The display

then shows the current setting with an asterisk. Then select

“T1” or “T2”.

2. Press the ▲ or ▼ button to select B5 (JIS), B5 (ISO), A5,

COM10 or DL then press the

Set

button to make the setting

effective.