beautypg.com

Kramer Electronics VS-3232V User Manual

Page 45

background image

The MENU Commands

41

8.7 The Main Firmware Version

The main firmware version menu shows information regarding the latest main

and Ethernet firmware versions, for example:

>

? (&''

? 5

9 :&

:

This information lets you decide whether a firmware upgrade is required.

It is recommended to upgrade the firmware only after consulting with the

Kramer technical support staff

8.8 Selecting the TOTAL RESET Option

The TOTAL RESET options requires you to press the blinking TAKE button

twice for double confirmation. Table 11 summarizes the TOTAL RESET

menu options:

Table 11: Total Reset Menu

Press:

To select:

After the change, the LCD displays:

1

All outputs OFF

, to

disconnect all the outputs

MATRIX erased

2

Factory default

, to the

factory default state

The Machine resets as follows:

OUT 1 is connected to IN 1, OUT 2 is connected to IN 2 … OUT 31

is connected to IN 31 and OUT 32 is connected to IN 32

The SYNC is extracted from the BNC-Genlock Input
All the interfaces are set to ON
The interface Reply is set to Reply
The interface protocol is set to Hex Kramer-2000
The DEFAULT SETUP is set to Matrix setup and cross-points