Test

This field displays one of the following possible states:

• Data Mode: Indicates no tests are active
• Payload Loopback: Indicates that a payload loopback is in progress
• Line Loopback: Indicates that a line loopback is in progress

PPP Interfaces

1-4

State

This field displays the current state of the four PPP interfaces as either
Enabled or Disabled.

LCP

This field displays the active state of this control protocol as either Up or
Down.

BCP

This field Displays the active state of this control protocol as either Up or
Down.

IPCP

This field Displays the active state of this control protocol as either Up or
Down.

Ethernet Ports

1-4

Status

This field displays the current status as either Up or Down.

Speed

This field Displays one of the following speeds as active:

• 10 Mbps, Half Duplex
• 10 Mbps, Full Duplex
• 100 Mbps, Half Duplex
• 100 Mbps, Full Duplex

Auxiliary Alarms

1-4

Status

This field displays the current alarm status as either Active or Cleared.

Severity

This field displays the current alarm severity. Severities are defined by the
customer and displayed as Critical, Major, Minor, Alert, or Info.

Power Feed

A/B

Status

This field displays the power feed (which connects to the rear of the
MX410/MX412) as either Normal or Failed.

PSU (MX410 Only)

A/B

State

This field displays the current status of the A/B PSUs as either Installed
or Removed.

Status

This field displays the current status of the A/B PSUs as Normal, Failed
(if the PSU is installed), or N/A (if the PSU is not installed).

Timing Source

Primary/

Secondary

Status

This field displays the status as either Normal or Failed.

Source

This field Displays internal or DS1 (1-4 on MX410 or 1-12 on MX412).

Table 5-21. Status Screen Fields (Continued)

Option

Description

Function