ADTRAN MX410 User Manual
Page 91
![background image](/manuals/43772/91/background.png)
MX410/MX412 System Manual
Menu Descriptions
61189500L1-1B
PRELIMINARY 5-41
Test
This field displays one of the following possible states:
• Data Mode: Indicates no tests are active
• Payload Loopback: Indicates that a payload loopback is in progress
• Line Loopback: Indicates that a line loopback is in progress
PPP Interfaces
1-4
State
This field displays the current state of the four PPP interfaces as either
Enabled or Disabled.
LCP
This field displays the active state of this control protocol as either Up or
Down.
BCP
This field Displays the active state of this control protocol as either Up or
Down.
IPCP
This field Displays the active state of this control protocol as either Up or
Down.
Ethernet Ports
1-4
Status
This field displays the current status as either Up or Down.
Speed
This field Displays one of the following speeds as active:
• 10 Mbps, Half Duplex
• 10 Mbps, Full Duplex
• 100 Mbps, Half Duplex
• 100 Mbps, Full Duplex
Auxiliary Alarms
1-4
Status
This field displays the current alarm status as either Active or Cleared.
Severity
This field displays the current alarm severity. Severities are defined by the
customer and displayed as Critical, Major, Minor, Alert, or Info.
Power Feed
A/B
Status
This field displays the power feed (which connects to the rear of the
MX410/MX412) as either Normal or Failed.
PSU (MX410 Only)
A/B
State
This field displays the current status of the A/B PSUs as either Installed
or Removed.
Status
This field displays the current status of the A/B PSUs as Normal, Failed
(if the PSU is installed), or N/A (if the PSU is not installed).
Timing Source
Primary/
Secondary
Status
This field displays the status as either Normal or Failed.
Source
This field Displays internal or DS1 (1-4 on MX410 or 1-12 on MX412).
Table 5-21. Status Screen Fields (Continued)
Option
Description
Function