Drop and Continue Application
The following applies to Remote Site #1 shown in
. In the Drop and Continue Appli-
cation, any combination of DS0s from one DS1 can be dropped out the other DS1 ports with
the remaining DS0s continuing through to the other DS1 interface. This enables the
bandwidth of one DS1 to deliver DS0s to several sites using one MX410 at each site.
Figure 3-2. Drop and Continue Application Diagram
The equipment needed for a Drop and Continue application is shown in
.
Table 3-1. Drop and Continue Application - Required Equipment
Part Number
Equipment
Quantity
1189500L1
or
1189512L1
MX410
MX412
1
1
1189501L1
MX410 PSU (MX410 only)
1 (2 for redundancy)
DS1
µ Wave/
Leased
DS1
DS1
µ Wave/
Leased
DS1
DS1
µ Wave/
Leased
DS1
MX410
DS1
DS1
V.
3
5
ETH1
Switch
MX410
DS1
DS1
V.
3
5
ETH1
Switch
24 DS0s
from Central Site
Original DS0s
Continue
Downstream;
All Ones in
Unmapped DS0s
Original DS0s
Continue
Downstream;
All Ones in
Unmapped DS0s
Drop DS0s
to Local
Equipment
DS1
DS1
DS1
DS1
DS1
Drop DS0s
to Local
Equipment
Drop DS0s
to PPP to
Control
Local
Equipment
via Ethernet
Drop DS0s
to PPP to
Control
Local
Equipment
via Ethernet
Remote
Site #2
Remote
Site #1
Central
Site