Remote Management of Other Systems using Terminal Server Ports and Ethernet Connectivity MX410/MX412 System Manual

3-18 PRELIMINARY

61189500L1-1B

Remote Management of Other Systems using Terminal Server

Ports and Ethernet Connectivity

In this application the Terminal Server ports on the MX410 are used to provide remote
management of other non-Ethernet based equipment at the same site. This requires
connecting the RS-232 craft ports of the other equipment to the Terminal Server ports of the
MX410. Establishing a Telnet session to the MX410 Terminal Server ports establishes access
to the other equipment. Up to four external devices can be accessed in this way.
The Ethernet ports on the MX410 are used to provide remote management of the other
Ethernet based equipment. This requires connecting the Ethernet ports of the other
equipment to the Ethernet ports on the MX410 (see

Figure 3-23

). Refer to

“PPP BCP/IPCP

Menu”

on page 5-32 for more information about PPP and IP.

Figure 3-23. MX410 Remote Management of Other Systems

The equipment needed for a Remote Management application is shown in

Table 3-4

.

Table 3-4. Remote Management Application - Required Equipment

Part Number

Equipment

Quantity

1189500L1
or
1189512L1

MX410

MX412

1

1

1189501L1

MX410 PSU (MX410 only)

1 (2 for redundancy)

Other Systems
Currently Managed
by the MX410 via
Ethernet Port to
Ethernet Port
Connections

Technician
Manages All
MX410 Units
and Other Systems
from Any Cell Site

Other Systems
Currently Managed
by the MX410 via
Terminal Server Port
to RS-232 Craft Port
Connections

MX410

IP

Ethernet Ports

Ethernet Ports

Terminal Server Ports

RS-232 Ports

DS1

µ Wave/

Leased

DS1

Original DS0s

Continue

Downstream;

All Ones in

Unmapped DS0s

DS1

µ Wave/

Leased

DS1

Original DS0s

Continue

Downstream;

All Ones in

Unmapped DS0s

DS1

DS1

DS1

DS1

Ethernet

Switch

MX410