beautypg.com

Fxs port, Psu slots, Fxs port -9 psu slots -9 – ADTRAN MX410 User Manual

Page 47: Table 4-6, Fxs options -9

background image

MX410/MX412 System Manual

Front Panel

61189500L1-1B

PRELIMINARY

4-9

FXS Port

The

FXS

port (MX412 only) provides a 2-wire analog interface between a Voice Frequency (VF)

transmission and a signaling facility. The FXS interface provides for simultaneous signaling in
each direction for use with 2-wire off-premises station lines, carrier extended PBX trunks, or
subscriber line foreign exchanges using a loop start signaling system. FXS options are shown
in

Table 4-6

.

WARNING

The FXS Port interface must not be metallically connected to inter-
faces which connect to the OSP or its wiring. The FXS interface is
designed for use as an intra-building interface only. The addition of
Primary Protectors is not sufficient protection in order to connect
the FXS interface metallically to OSP wiring.

PSU Slots

The MX410 houses up to two hot-swappable PSUs that can provide power redundancy. At
least one MX410 PSU (P/N 1189501L1) must be inserted into the MX410 for the MX410 to
function. To remove a PSU, remove the screws that hold it in place and carefully pull the PSU
straight out of the MX410. A blank PSU cover (P/N 1189502L1) should be used to cover an
unused PSU slot. Refer to

“LED Indicators”

on page 4-10 after power is applied and a PSU is

inserted for the MX410 status.
The MX412 contains an internal power supply.

Table 4-6. FXS Options

Mode

Description

Loop Start

Selects ANSI T1.403 FXS Loop Start mode of operation

PLAR D4

Selects Private Line Automatic Ringdown where onhook = 00.
Signaling must match the PLAR unit at the distant end.

PLAR D3

Selects Private Line Automatic Ringdown where onhook = 11.
Signaling must match the PLAR unit at the distant end.

FX Ringdown

PLAR mode of operation that allows for an FXS Loop Start unit on the
distant end.