Primary Timing Mode Menu
The Primary Timing Mode menu (see
) is used to set the primary timing mode for
the selected DS1 port (1-4 on the MX410 and 1-12 on the MX412).
Figure 5-10. Primary Timing Mode Menu
The Primary Timing Mode menu options are shown in
.
CAUTION
The entire MX410/MX412 is timed from a single source and all
transmitters are synchronized. Any device attached to the MX410/
MX412 should be placed in loop or line timing mode, unless it is
providing timing. If an attached device is providing timing, the
MX410/MX412 must be configured to use this interface as its pri-
mary timing source. If the MX410/MX412 is set for internal timing,
all devices connected to it must be set to loop or line timing.
Table 5-7. Primary Timing Mode Menu Options
Option
Description
Function
1
Internal
This option sets the timing mode to internal.
2
DS1 1
This option sets the timing mode to DS1 1.
3
DS1 2
This option sets the timing mode to DS1 2.
4
DS1 3
This option sets the timing mode to DS1 3.
5
DS1 4
This option sets the timing mode to DS1 4.
MX410 MM/DD/YY HH:MM
Active Alarms: CRITICAL MAJOR ID: MX410
Primary Timing Mode : Internal
1 - Internal
2 - DS1 1
3 - DS1 2
4 - DS1 3
5 - DS1 4
Selection : '?' - System Help Screen