beautypg.com

Bridge menu – Allied Telesis AT-VIEW PLUS 3.0 DEVICE MANAGEMENT User Manual

Page 68

background image

Allied Telesyn

AT-VIEW PLUS

DEVICE MANAGEMENT

Note

-The current firmware version does not allow the Power A Status and Power B Status

parameters to be configured. Attempting to configure these parameters will result in the error
message: "The error occurred with 'Set' operation. Error: gen Error.".


Line Card Info

Displays information for each line card including line card type and line card temperature.


MAC Address Table

Displays a list of static MAC address configured on the switch.

Note

- Valid MIB Set values for the MAC Address Entry Status parameter are 'active', 'not in

service' and 'destroy'. Attempting to set this parameter to any other value will result in error
message: "The error occurred with 'Set' operation. Error: bad value".


Reset

Resets the switch.


Telnet

Starts a Telnet connection to the switch.


WEB Browser

Connects to the switch's HTTP server.

Bridge Menu

From the Bridge menu, you can view and edit bridge information such as the forwarding database
and the spanning tree status.

Forwarding Database

Displays the Forwarding Database table.

Note

- It may take some time to retrieve Forwarding Database information. As a result, all

the Forwarding Database parameters may reflect the value 'retry over occurred'. To avoid
this, click on File -> Property -> Polling options and set the Polling Interval parameter to 25
seconds or longer.


Discard/Aging Time Info

Displays information about the number of address entries that were learned but discarded
because either there was a lack of memory or the entry's aging timer expired.


Spanning Tree Info

Displays spanning tree parameters such as spanning tree status and spanning tree version.

PN 613-50665 Rev A

Page 68 of 257