6.5.2 Display Data Type of Chart
Specifies how to display data on graphs or charts. Select one of the following
two options.
Absolute
Displays a value as it is.
Relative
Displays a change in the value per second. This is (Current value -
Previous value) / Polling Interval.
Note
- The change here takes effect the next time the data is polled.
6.5.3 Regist Menu
Add this window to the User Menu. If you want to view the current window
repeatedly, do the following.
1. Click "Regist menu".
2. On "Regist Menu Item" dialog box, select one of "Common Menu" or
"Target Menu". Common Menu is always accessible regardless of the
target device. Target Menu can be accessed only when connected to the
same specific device type.
3. Optionally, change the MenuItem Name. This string is displayed as the
menu item name.
4. Click OK.
6.5.4 Save Polling Data
Save the collected data to a file. When you click this button, the Polling Data
Save dialog box appears and lets you specify the name of the file and the file
format. To start saving data, click OK in the Save Polling Data dialog box. The
Save polling data button changes to "Saving polled data". To close the file and
stop saving data, click this button again.
The file format can be selected from the following options:
CSV Format
Save data in comma-separated values (CSV) format.
TAB Format
Save data in Tab-separated values (TSV) format.