beautypg.com

2 display data type of chart, 3 regist menu, 4 save polling data – Allied Telesis AlliedView-EMS 3.10 DEVICE MANAGER User Manual

Page 82: Display data type of chart, Regist menu, Save polling data

background image


AlliedView™-EMS 3.10 Device Manager User’s Guide

Page 82 of 133

6.5.2 Display Data Type of Chart

Specifies how to display data on graphs or charts. Select one of the following
two options.


Absolute

Displays a value as it is.

Relative

Displays a change in the value per second. This is (Current value -
Previous value) / Polling Interval.

Note

- The change here takes effect the next time the data is polled.

6.5.3 Regist Menu

Add this window to the User Menu. If you want to view the current window
repeatedly, do the following.

1. Click "Regist menu".
2. On "Regist Menu Item" dialog box, select one of "Common Menu" or

"Target Menu". Common Menu is always accessible regardless of the

target device. Target Menu can be accessed only when connected to the
same specific device type.

3. Optionally, change the MenuItem Name. This string is displayed as the

menu item name.

4. Click OK.

6.5.4 Save Polling Data

Save the collected data to a file. When you click this button, the Polling Data

Save dialog box appears and lets you specify the name of the file and the file
format. To start saving data, click OK in the Save Polling Data dialog box. The
Save polling data button changes to "Saving polled data". To close the file and
stop saving data, click this button again.

The file format can be selected from the following options:

CSV Format

Save data in comma-separated values (CSV) format.

TAB Format

Save data in Tab-separated values (TSV) format.