High Country Tek emc-3L User Manual
Page 47
Process PI Variables
Name Description
Range
Name.Set-point
The desired % set point position for the
output
0 to 100%
Name.Feedback
The % feedback position for the output
0 to 100%
Name.ProErr
Error = Set point – Feedback
16 bit signed integer
Name.ProSumErr
Error accumulated over time
0 – 65535
Name.ProP
Process Proportional Term Constant “P”
0 – 255
Name.ProI
Process Proportional Term Constant “I”
0 – 255
Name.ProItime
Update / Integration Time
0.0 to 650.00 s
Name.Cur
Current actual * CurGain = amps
0 – 3.5 amps
Name.RampCur
Current ramped Currend*CurGain= amps 0 – 3.5 amps
Name.CurErr
Current Error = RampCur – Cur
16 bit signed integer
Name.CurSumErr
Current Error accumulated over time
0 – 65535
Name.CurP
Current Proportional Term Constant “P”
0 – 255
Name.CurI
Current Proportional Term Constant “I”
0 – 255
Name.MinCurA
Minimum Current Coil A *.001 = amps
0 – 3.5 amps
Name.MaxCurA
Maximum Current Coil A *.001 = amps
0 – 3.5 amps
Name.MinCurB
Minimum Current Coil B *.001 = amps
0 – 3.5 amps
Name.MaxCurB
Maximum Current Coil B *.001 = amps
0 – 3.5 amps
Name.Config
Configuration Word – Output, Process,
Coil
P/N: 021-00163, Rev. A.0 - for V5.2 Tools
Page | 47